Skip to main content

Advanced Manufacturing: Industrial Maintenance Technology: Heating and Humidification (for Industrial Maint.) 470363 (2026–2027)

Other Kentucky CTE sets

Practice and perform safe shop procedures at all times.1

  • 1

    Practice and perform safe shop procedures at all times.1

Apply the technical math required for employment opportunities in maintenance.2

  • 2

    Apply the technical math required for employment opportunities in maintenance.2

Perform all duties with emphasis on integrity, responsibility, quality, discipline and teamwork.3

  • 3

    Perform all duties with emphasis on integrity, responsibility, quality, discipline and teamwork.3

Adjust valves.4

  • 4

    Adjust valves.4

Check coil resistance of a valve coil.5

  • 5

    Check coil resistance of a valve coil.5

Test gas valve operation.6

  • 6

    Test gas valve operation.6

Check the voltage at gas valve operator.7

  • 7

    Check the voltage at gas valve operator.7

Check pressure at inlet vs. outlet of gas valve.8

  • 8

    Check pressure at inlet vs. outlet of gas valve.8

Perform a regular conversion on a gas valve from natural gas to LP or reverse: low, line voltage, redundant, two-stage, and modulating.9

  • 9

    Perform a regular conversion on a gas valve from natural gas to LP or reverse: low, line voltage, redundant, two-stage, and modulating.9

Explain the operation of a solenoid valve.10

  • 10

    Explain the operation of a solenoid valve.10

Explain direct vs. servo regulation.11

  • 11

    Explain direct vs. servo regulation.11

Identify limited, non-adjustable and adjustable regulators.12

  • 12

    Identify limited, non-adjustable and adjustable regulators.12

Determine application of gas valves.13

  • 13

    Determine application of gas valves.13

Differentiate between pilot proving devices.14

  • 14

    Differentiate between pilot proving devices.14

Explain the operation of flame rod, mercury flame switch, bimetal, and millivolt flame sensors.15

  • 15

    Explain the operation of flame rod, mercury flame switch, bimetal, and millivolt flame sensors.15

Test and change a thermocouple flame sensor.16

  • 16

    Test and change a thermocouple flame sensor.16

Test spark ignition modules.17

  • 17

    Test spark ignition modules.17

Perform safety lockout procedures for burners.18

  • 18

    Perform safety lockout procedures for burners.18

Measure resistance of a cad cell during operation.19

  • 19

    Measure resistance of a cad cell during operation.19

Explain the operation of an oil delay valve.20

  • 20

    Explain the operation of an oil delay valve.20

Identify and install residential heating and cooling thermostats.21

  • 21

    Identify and install residential heating and cooling thermostats.21

Test a fan/limit control to identify a set point of control.22

  • 22

    Test a fan/limit control to identify a set point of control.22

Wire a complete heating system—line and low voltage.23

  • 23

    Wire a complete heating system—line and low voltage.23

Identify controls for heating and cooling.24

  • 24

    Identify controls for heating and cooling.24

Wire a humidistat into electrical circuit.25

  • 25

    Wire a humidistat into electrical circuit.25

Wire control circuit for electronic air cleaner.26

  • 26

    Wire control circuit for electronic air cleaner.26

Test and adjust the fuel system of furnace.27

  • 27

    Test and adjust the fuel system of furnace.27

Check the ignition system.28

  • 28

    Check the ignition system.28

De-rate or change over a gas burner.29

  • 29

    De-rate or change over a gas burner.29

Adjust burner system to recommended efficiency.30

  • 30

    Adjust burner system to recommended efficiency.30

Check for proper temperature rise across the furnace.31

  • 31

    Check for proper temperature rise across the furnace.31

Test all safety controls.32

  • 32

    Test all safety controls.32

Set proper air distribution in house.33

  • 33

    Set proper air distribution in house.33

Remove, install, and adjust blower motor and/or belt.34

  • 34

    Remove, install, and adjust blower motor and/or belt.34

Clean the pilot assembly.35

  • 35

    Clean the pilot assembly.35

Adjust the regulator.36

  • 36

    Adjust the regulator.36

Observe proper draft conditions.37

  • 37

    Observe proper draft conditions.37

Oil motor(s) and bearings.38

  • 38

    Oil motor(s) and bearings.38

Check and adjust the heat anticipator.39

  • 39

    Check and adjust the heat anticipator.39

Check circulator for alignment and lubrication.40

  • 40

    Check circulator for alignment and lubrication.40

Set aquastat.41

  • 41

    Set aquastat.41

Check water-regulating valve operator.42

  • 42

    Check water-regulating valve operator.42

Inspect/change zone valve operator.43

  • 43

    Inspect/change zone valve operator.43

Remove air from water system.44

  • 44

    Remove air from water system.44

Wire a multi-zone/multi-pump hydronic system.45

  • 45

    Wire a multi-zone/multi-pump hydronic system.45

Identify types of hydronic piping systems.46

  • 46

    Identify types of hydronic piping systems.46

Test boiler efficiency and clean if necessary.47

  • 47

    Test boiler efficiency and clean if necessary.47

Oil motor(s).48

  • 48

    Oil motor(s).48

Check and adjust the heat anticipator.49

  • 49

    Check and adjust the heat anticipator.49

Perform pressure checks on the fuel system.50

  • 50

    Perform pressure checks on the fuel system.50

Perform pressure checks on the venting system.51

  • 51

    Perform pressure checks on the venting system.51

Measure temperature difference across heating and cooling equipment.52

  • 52

    Measure temperature difference across heating and cooling equipment.52

Adjust individual register outlets to properly balance system.53

  • 53

    Adjust individual register outlets to properly balance system.53

Describe the reasons for codes.54

  • 54

    Describe the reasons for codes.54

Discuss three model codes: boca, standard, and uniform.55

  • 55

    Discuss three model codes: boca, standard, and uniform.55

Identify the codes and standards for the applicable area, locality, or state.56

  • 56

    Identify the codes and standards for the applicable area, locality, or state.56

Discuss the relationship between codes and manufacturers’ installation instructions.57

  • 57

    Discuss the relationship between codes and manufacturers’ installation instructions.57

Identify standards not covered by codes: ARI (Air-Conditioning and Refrigeration Institute), ASHRAE (American Society of Heating, Refrigeration, and Air Conditioning Engineers), and SMACNA (Sheet Metal and Air Conditioning Contractors National Association).58

  • 58

    Identify standards not covered by codes: ARI (Air-Conditioning and Refrigeration Institute), ASHRAE (American Society of Heating, Refrigeration, and Air Conditioning Engineers), and SMACNA (Sheet Metal and Air Conditioning Contractors National Association).58

Demonstrate good customer relations in a classroom situation.59

  • 59

    Demonstrate good customer relations in a classroom situation.59

Explain the importance of manufacturers’ installation and operation requirements.60

  • 60

    Explain the importance of manufacturers’ installation and operation requirements.60

Determine equipment electrical requirements.61

  • 61

    Determine equipment electrical requirements.61

Verify equipment airflow and distribution requirements.62

  • 62

    Verify equipment airflow and distribution requirements.62

Check operation of all electrical control components.63

  • 63

    Check operation of all electrical control components.63

Check operation of gas train components and measurements.64

  • 64

    Check operation of gas train components and measurements.64

Demonstrate use of tools and instruments.65

  • 65

    Demonstrate use of tools and instruments.65

Check oil burner components and measurements.66

  • 66

    Check oil burner components and measurements.66

Check ignition systems while following all safety principles.67

  • 67

    Check ignition systems while following all safety principles.67

Evaluate fuel supply systems.68

  • 68

    Evaluate fuel supply systems.68

Test for proper combustion.69

  • 69

    Test for proper combustion.69

Check electrical components for operation and wiring connections.70

  • 70

    Check electrical components for operation and wiring connections.70

Check for correct heating input and adjust to manufacturers’ specifications.71

  • 71

    Check for correct heating input and adjust to manufacturers’ specifications.71

Read and demonstrate an understanding of electrical wiring diagrams.72

  • 72

    Read and demonstrate an understanding of electrical wiring diagrams.72

Use tools and test equipment appropriately while following safety practices.73

  • 73

    Use tools and test equipment appropriately while following safety practices.73

Demonstrate an understanding of combustion theory.74

  • 74

    Demonstrate an understanding of combustion theory.74

Determine air requirements.75

  • 75

    Determine air requirements.75

Develop a systematic way to diagnose system problems and demonstrate them in class.76

  • 76

    Develop a systematic way to diagnose system problems and demonstrate them in class.76

Determine cause of failure in a heating system.77

  • 77

    Determine cause of failure in a heating system.77

Identify and describe all possible causes of failure and how to eliminate causes.78

  • 78

    Identify and describe all possible causes of failure and how to eliminate causes.78

Verify system operation.79

  • 79

    Verify system operation.79

Write a service report.80

  • 80

    Write a service report.80

Measure chimney draft with a draft gauge.81

  • 81

    Measure chimney draft with a draft gauge.81

Perform an efficiency test on an oil-gas burner: smoke test, CO2 test, and 02 test.82

  • 82

    Perform an efficiency test on an oil-gas burner: smoke test, CO2 test, and 02 test.82

Determine the efficiency of an oil pump using a vacuum gauge and a pressure gauge.83

  • 83

    Determine the efficiency of an oil pump using a vacuum gauge and a pressure gauge.83

Determine the relative humidity using a sling psychrometer.84

  • 84

    Determine the relative humidity using a sling psychrometer.84

Measure gas pressure with a U-tube manometer.85

  • 85

    Measure gas pressure with a U-tube manometer.85

Frequently asked questions

What grade levels do these standards cover?